Solar Inverters - Square wave Solar Inverters 660-2000 Watt
660 Watt Juta Square wave Solar Inverter
The "JUTA" 660 Watt solar inverter transfers 12V Direct Current to 220V Alternating Current for the use of home appliances such as TV's, radios, fax machines and hair clippers
Protective Functions
- Overloading Protection: When the power consumption of the appliance/appliances exceed the total power of the solar inverter. It will then revert to the protection state within 20 seconds untill you reduce the load
- Short circuit protection: If an appliance short circuits. The solar inverter will revert to the protection state untill the appliance is removed.
- Thermal protection: If the temperature of the solar inverter gets too hot it will revert to the protection state untill it is turned off to cool down.
- Reverse polarity protection: If connected incorrectly no current will pass through the solar inverter(The hand of the voltage meter will point to the reverse direction)
| Model: | W-660 | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Output Power | =660W | |||||||||
| Input Voltage | 12V | |||||||||
| Output Voltage | 185V~255V | |||||||||
| Max Own Consumption | =1.5% | |||||||||
| Output Frequency | 50~60Hz | |||||||||
| Output Wave | Modified Square Wave | |||||||||
| The half Load efficiancy | 88% | |||||||||
| Dimensions mm (LxWxH) | 320x240x140 | |||||||||
| Net weight | 8.7kg | |||||||||
660 Watt Juta Square wave Solar Inverter Built in charger
The "JUTA" 660 Watt solar inverter with a built in charger is perfect for load shedding as all you need to add is a battery and you can run your TV, DVD player, DSTV and some lights. It is also very portable and can be used wherever it is needed.
Protective Functions
- Overloading Protection: When the power consumption of the appliance/appliances exceed the total power of the solar inverter. It will then revert to the protection state within 20 seconds untill you reduce the load
- Short circuit protection: If an appliance short circuits. The solar inverter will revert to the protection state untill the appliance is removed.
- Thermal protection: If the temperature of the solar inverter gets too hot it will revert to the protection state untill it is turned off to cool down.
- Reverse polarity protection: If connected incorrectly no current will pass through the solar inverter(The hand of the voltage meter will point to the reverse direction)
| Model: | W-660 | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Output Power | =660W | |||||||||
| Input Voltage | 12V | |||||||||
| Output Voltage | 185V~255V | |||||||||
| Max Own Consumption | =1.5% | |||||||||
| Output Frequency | 50~60Hz | |||||||||
| Output Wave | Modified Square Wave | |||||||||
| The half Load efficiancy | 88% | |||||||||
| Dimensions mm (LxWxH) | 320x240x140 | |||||||||
| Net weight | 8.7kg | |||||||||
1500 Watt Juta Square wave Solar Inverter
The "JUTA" 1500 Watt solar inverter transfers 12V Direct Current to 220V Alternating Current for the use of home appliances such as TV's, radios, fax machines and hair clippers
Protective Functions
- Overloading Protection: When the power consumption of the appliance/appliances exceed the total power of the solar inverter. It will then revert to the protection state within 20 seconds untill you reduce the load
- Short circuit protection: If an appliance short circuits. The solar inverter will revert to the protection state untill the appliance is removed.
- Thermal protection: If the temperature of the solar inverter gets too hot it will revert to the protection state untill it is turned off to cool down.
- Reverse polarity protection: If connected incorrectly no current will pass through the solar inverter(The hand of the voltage meter will point to the reverse direction)
| Model: | W-1000 | W-1200 | W-1500 | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Power | =1000W | =1200W | =1500W | |||||||
| Input Voltage | 24V | 24V | 24V | |||||||
| Output Voltage | 190V~250V | |||||||||
| Max Own Consumption | =1.5% | |||||||||
| Output Frequency | 50~60Hz | |||||||||
| Output Wave | Modified Square Wave | |||||||||
| The half Load efficiancy | 90% | 90% | 91% | |||||||
| Dimensions mm (LxWxH) | 300x325x155 | 300x325x155 | 325x345x165 | |||||||
| Weight | 14.3kg | 14.5kg | 15.8kg | |||||||
2000 Watt Juta Square wave Solar Inverter
The "JUTA" 2000 Watt solar inverter transfers 12V Direct Current to 220V Alternating Current for the use of home appliances such as TV's, radios, fax machines and hair clippers
Protective Functions
- Overloading Protection: When the power consumption of the appliance/appliances exceed the total power of the solar inverter. It will then revert to the protection state within 20 seconds untill you reduce the load
- Short circuit protection: If an appliance short circuits. The solar inverter will revert to the protection state untill the appliance is removed.
- Thermal protection: If the temperature of the solar inverter gets too hot it will revert to the protection state untill it is turned off to cool down.
- Reverse polarity protection: If connected incorrectly no current will pass through the solar inverter(The hand of the voltage meter will point to the reverse direction)
| Model: | W-2000 | W-3000 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Power | =2000W | =3000W | ||||||||
| Input Voltage | 24V | 36V,48V | ||||||||
| Output Voltage | 195V~245V | 200V~240V | ||||||||
| Max Own Consumption | =1.5% | |||||||||
| Output Frequency | 50~60Hz | |||||||||
| Output Wave | Modified Square Wave | |||||||||
| The half Load efficiancy | 92% | 93% | ||||||||
| Dimensions mm (LxWxH) | 355x350x165 | 365x355x175 | ||||||||